您当前位置:首页 > 设备频道 > 供求信息 > 供应信息 > 北京设备网 > 详情

WOHNER母线安装 33198

0
  • 北京碧海飞鹏科技有限公司
  • 联系人:黄刚
  • 电话:13651037564
  • 手机:010-61283642
  • 传真:010-61283642
  • 地址:北京市大兴区小白楼北白楼路1号华成大厦三层
产品简介

Description Part No.: 33198 QUADRON®CrossLinkBreaker NH fuse switch disconneor size 00, 160 A 3-pole, 60 mm system, top.bottom by rotating, for busbars 12,15,20,25,30x5/10, double-T.triple-T- seion System 60mm-System classic Produ Advantages Adapter system for CrossLink® Technology Safe.quick refitting of top / bottom conneion, live parts remain shock proteed Snap on busbar provides easy.secure contas The shock proteion cover is in 2 pieces to provide for safe conneion of cables Can be mounted over the flat busbar supports Produ Group Subgroup 9 24 Standards IEC 60947-1:2004 IEC 60947-3:1999 IEC 60947-1:2007 IEC 60947-3:2008 EN 60947-1:2007 EN 60947-3:2009 DIN EN 60947-1/04.08 DIN EN 60947-3/02.10 Approvals VDE, IEC (CB), Germanischer Lloyd, GOST, CCC Type No.: QCB-NH 00 CCC certificate: 2010010302403934 Elerical Data 690 V AC / 440 V DC / 160 A type of current AC (50-60Hz) / DC rated insulation voltage 800V rated surge withstand capacitiy 6kV conditional rated short circuit current 50 kA utilisation categories AC-21B (690 V), AC-22B (500 V), DC-21B (220 V), DC-21B (440 V / 100 A), DC-22B (220 V / 63A) DC specifications: 2 current paths (L1, L2) in series with fuse links gL/gG 500V/160A,690V/125A for fuse links to IEC 60269-2 / DIN VDE 0636-2 size 00 up to 12 W AC-20B (1000 V), DC-20B (1000 V) pollution degree 2 if application more than DC 440V /AC 690V.AC 160A: do not operate under load According to the AC.DC switching charaeristics.in consideration of the overload conditions, the following distances to earth metal parts have to be provided. - top 100mm, side 50mm By using as a disconneor (switching not under load) the mentioned distances are not applicable. Component unit, front side degree of proteion IP30 according to DIN EN 60529; degree of proteion near terminal depends on installation. Adapter module, front side degree of proteion IP20 according to DIN EN 60529 (safety against finger touch). Mechanical Data Width x Height x Depth (mm): 106 x 200 x 97 Weight (kg/100): 100 busbar conneion: screw less with externally spring-loaded contas, easy adjustment from 5 to 10 mm busbars.reverse Conneions Box terminal: 1,5 -70mm² flexible cables, direly.with wire-end ferrules*, depending on contour of the insulated lead 95mm² could be conneable 1,5 -10mm² solid round 16 -70mm² stranded round 2x10mm², 2x16mm².2x25mm² flexible with wire-end ferrules, identical cables placed side by side, crimping square 2x6 -50mm² flexible identical cables placed side by side la. Cu. 9-13 mm wide Terminal space 13mm x 13mm (*flexible cables of maximum cross-seion may not fit when using wire-end ferrule) Material Charaeristics Main body: temperature stability 125°C, self-extinguishing in acc. to UL 94, creepage resistance I 200, Shock proteion cover: temperature stability 120°C, self-extinguishing in acc. to UL 94, creepage resistance I 200 Handle: temperature stability 120°C, self-extinguishing in acc. to UL 94, creepage resistance I 200 Adapter plate: temperature stability 125°C, self-extinguishing in acc. to UL 94, creepage resistance I 200, Contas: spring-loaded contas, copper, silver plated Versions See 33 398 for variant with screw M8 See 33 324 for variant with fuse monitoring See 33 206 for variant with eleromechanically fuse monitoring Pack Size 1

About Us - 关于我们 - 服务列表 - 付费指导 - 媒体合作 - 广告服务 - 版权声明 - 联系我们 - 网站地图 - 常见问题 - 友情链接
Copyright©2014安装信息网 www.zgazxxw.com. All rights reserved.
服务热线:4000-293-296 邮箱:zgazxxw@126.com 豫ICP备18030500号-4
未经过本站允许,请勿将本站内容传播或复制
安全联盟认证